作者:WANG Jiandong;GE Changchun;SHEN Weiping;
作者单位:School of Material Science and Engineering, USTB, Beijing 100083 China
刊名:China's Refractories
ISSN:1004-4493
出版年:2006-01-05
卷:15
期:3
起页:13
止页:16
分类号:TQ175
语种:英文
关键词:Refining furnace;Magnesia-Calcia brick;Microstructure;Corrosion mechanism;
内容简介Residual MgO-CaO brick after being used in AOD furnace was determined by OM, SEM and EDAX. Corrosion mechanism of MgO-CaO brick as furnace lining was studied. Results show that The corrosion of MgO-CaO brick is mainly attributed to the solution and infiltration of silicate liquid phase. Transverse cracks between reacted zone and original zone are parallel to the working face, which is an important factor for deteriorating the corrosion of MgO-CaO bricks.